WANLIN-303
Standalone photoelectric smoke alarm family
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
Export product-family resource
Standalone Fire Detection Guide for OEM Sourcing explains smoke detector choices, model-family differences, buyer checks, documentation limits and OEM...
Direct answer
An export standalone smoke alarm detects smoke and provides a local audible warning without requiring a conventional fire alarm control panel. For OEM sourcing, buyers should first define the protected space, required local alarm behaviour, reporting method, power arrangement and destination-market evidence.
This page is written for importers, distributors and private-label procurement teams. It is a product-family selection resource, not a claim that every variant has the same approval, radio module or market access.

Model reference image
The image identifies a WANLIN-307 family reference. Radio, power, label and evidence scope can differ by controlled configuration; confirm the SKU/BOM before using any formal product or compliance statement.
Open the WANLIN-307 product passport · Review the public evidence center
Verified manual data
Evidence scope: WANLIN-307 user manual, Ver 1.0. Documented manual configuration only; radio, platform, power and market variants require separate SKU/BOM confirmation.
| Detection principle | Infrared photoelectric smoke sensing with MCU processing |
|---|---|
| Rated working voltage | DC 3 V |
| Battery capacity | 2400 mAh |
| Standby current | ≤ 6 μA |
| Alarm current | ≤ 100 mA |
| Sound pressure | > 80 dB(A) at 3 m directly in front |
| Operating temperature | −10 °C to +50 °C |
| Relative humidity | ≤ 95% RH at 40 °C ± 2 °C |
| Alarm output | Audible and visual alarm |
| Low-voltage indication | Below 2.7 V; indicator and one chirp about every 40 s |
| Normal indicator | Indicator illuminates about every 40 s |
| Approximate weight | 140 g including battery |
| Manual-listed execution standard | GB 20517-2006 |
| Installation reference | GB 50116-2013; final layout must follow project design requirements |
Important: “GB 20517-2006” is presented here as the execution standard stated by this manual. This wording is not a third-party certificate claim and does not establish destination-market acceptance. The manual also advises against use where relative humidity exceeds 95%, air speed exceeds 5 m/s, or heavy dust, water mist, steam, oil mist or corrosive gas is present.
Site-specific planning lens
For a formal compliance statement, match the evidence to the exact model, SKU/BOM, radio or power version, legal certificate holder, standard edition, validity period and destination market.
A retrofit project should record mounting constraints, existing network availability and whether the buyer expects a self-contained device or integration with a wider platform.
Project buyers should separate mandatory requirements from preferences so unsupported options can be identified before samples or labels are prepared.
For this site's OEM sourcing focus, the planning lens is “Fire Alarm Input and Output Modules for Export Projects.” Start with the decision that changes the architecture most: local alarm only, or local alarm plus remote event reporting.
Existing site context: Find practical guidance on Wanlin Fire fire alarm input and output modules for export projects, including product selection, system planning, OEM/ODM service and export project support. Use that context to define the application; it does not replace model-specific technical or compliance review.
Last reviewed: 2026-11-02 · Reviewed by Wanlin Fire Equipment for product-family and evidence-boundary consistency.
WANLIN-303
Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.
WANLIN-307
Candidate configurations may include standalone, 433 MHz, LoRa, 4G or NB-IoT; availability and evidence must be confirmed per SKU/BOM.
WANLIN-309
Use when the project requires a local alarm plus a defined reporting path; verify gateway, network and destination-market requirements.
WANLIN-370
A smoke/heat/carbon-monoxide combination concept is not interchangeable with a smoke-only alarm; confirm the required sensing functions first.
Decision rule: use a formal claim only when the evidence is current and matches the model, configuration, legal holder, standard and market. Otherwise the status remains pending verification.
Answers for buyers
A basic standalone alarm provides local detection and sound without a conventional panel. Connected variants may use a gateway, cloud platform or communication module, depending on the selected architecture.
A certificate states a defined certification scope, while a test report records tests on identified samples or configurations. Neither should be extended to an unlisted model or variant.
No. Brochures support initial selection, but formal approval should use model-specific specifications, configuration records, applicable evidence, label artwork and current instructions.
Check model marking, sensing function, alarm behaviour, communication path, power arrangement, gateway or platform interaction, label artwork, manual revision and the evidence pack.
The importer or another qualified party familiar with the destination requirements should confirm acceptance against current documents before an order is represented as market ready.
Send the destination country, application, quantity, reporting method, preferred power arrangement and required delivery schedule to wanlinfirecontrol@163.com. Recommendations and formal claims remain subject to exact-model evidence review.
Browse product information · Read technical FAQs · Contact Wanlin Fire